FOAMGLAS® Boards

  • FOAMGLAS® WALL BOARD T3+ New

    Some application areas:

    • façades
    • cavity walls
    • belowgrade: walls
    • walls and soffits; interior insulation behind brick lining, plasterboard stud wall construction

     

    Thickness*

    in mm

    Dimensions*

    in mm

    Density (± 10%)
    (EN 1602) in kg/m3
    Thermal conductivity λD (EN ISO 10456) Compressive Strength
    (EN 826-A)

    50-180

    1200x600

    100

    ≤ 0.036 W/(m.K)

    ≥ 500 kPa


    *Other dimensions and thicknesses available upon request

    Product data sheet PDS_FG_WALL_BOARD_T3plus_20170102-UK.pdf
  • FOAMGLAS® READY BOARD T3+ New

    Some application areas:

    • flat roofs: cold bonding on steel deck
    • belowgrade: walls
    • Interior insulation: floors

     

    Thickness*

    in mm

    Dimensions*

    in mm

    Density (± 10%)
    (EN 1602) in kg/m3
    Thermal conductivity λD (EN ISO 10456) Compressive Strength
    (EN 826-A)

    50-180

    1200x600

    100

    ≤ 0.036 W/(m.K)

    ≥ 500 kPa


    *Other dimensions and thicknesses available upon request

    Product data sheet PDS_FG_READY_BOARD_T3plus_20161102-UK.pdf
  • FOAMGLAS® READY BLOCK T3+ New

    Some application areas:

    • flat roofs: bonding on concrete, metal deck and special roofs
    • belowgrade: walls & floors
    • interior insulation: floors

     

    Thickness*

    in mm

    Dimensions*

    in mm

    Density (± 10%)
    (EN 1602) in kg/m3
    Thermal conductivity λD (EN ISO 10456) Compressive Strength
    (EN 826-A)

    50-180

    600x450

    100

    ≤ 0.036 W/(m.K)

    ≥ 500 kPa


    *Other dimensions and thicknesses available upon request

    Product data sheet PDS_FG_READY_BLOCK_T3plus_20170102-UK.pdf
  • FOAMGLAS® ROOF BOARD G2 T3+ New

    Some application areas:

    • flat roofs (cold bonding on concrete)

     

    Thickness*

    in mm

    Dimensions*

    in mm

    Density (± 10%)
    (EN 1602) in kg/m3
    Thermal conductivity λD (EN ISO 10456) Compressive Strength
    (EN 826-A)

    50-180

    1200x600

    100

    ≤ 0.036 W/(m.K)

    ≥ 500 kPa


    *Other dimensions and thicknesses available upon request

    Product data sheet PDS_FG_ROOF_BOARD_G2_T3plus_20170102-UK.pdf
  • FOAMGLAS® WALL BOARD W+F

    Application area:

    No compressive strength requirements.
    Insulation of:

    • Façades
    • Walls and soffits (interior insulation brick lining or metal stud construction)

     

    Thickness*

    in mm

    Dimensions* in mm

    Density (± 10%)

    (EN 1602) in kg/m3

    Thermal conductivity λD (EN ISO 10456)

    Compressive Strength
    (EN 826-A)

    40-140mm

    1200x600

    100

    ≤ 0.038 W/(m.K)

    ≥ 400 kPa

     

    *Other dimensions and thicknesses available upon request

    Product data sheet PDS_PC_2-1-1_WALL_BOARD_WF-UK_0413.pdf
    Safety data sheet SDS_PC_BOARDS_BLOCKS_PERINSUL_20121217-UK-AE-INT.pdf
    National BIM Library http://www.nationalbimlibrary.com/foamglas/foamglas-board-w-f-
  • FOAMGLAS® FLOOR BOARD T4+

    Application area:

    Insulation of:

    • Floors
    • Façades (cavity wall insulation, f.i. between 2 concrete shells)

     

    Thickness*

    in mm

    Dimensions* in mm

    Density (± 10%)

    (EN 1602) in kg/m3

    Thermal conductivity λD (EN ISO 10456)

    Compressive Strength
    (EN 826-A)

    40-180

    1200x600

    115

    ≤ 0.041 W/(m.K)

    ≥ 600 kPa

     

    *Other dimensions and thicknesses available upon request

    Product data sheet PDS_PC_2-1-2_FLOOR_BOARD_T4-UK_0413.pdf
    Safety data sheet SDS_PC_BOARDS_BLOCKS_PERINSUL_20121217-UK-AE-INT.pdf
  • FOAMGLAS® FLOOR BOARD S3

    Application area:

    For high compressive strength requirements
    Insulation of:

    • Floors
    • Foundation slabs

     

    Thickness*

    in mm

    Dimensions* in mm

    Density (± 10%)

    (EN 1602) in kg/m3

    Thermal conductivity λD (EN ISO 10456)

    Compressive Strength
    (EN 826-A)

    40-180

    1200x600

    130

    ≤ 0.045 W/(m.K)

    ≥ 900 kPa

     

    *Other dimensions and thicknesses available upon request

    Safety data sheet SDS_PC_BOARDS_BLOCKS_PERINSUL_20121217-UK-AE-INT.pdf
    National BIM Library http://www.nationalbimlibrary.com/foamglas/foamglas-s3-board
  • FOAMGLAS® FLOOR BOARD F

    Application area:

    For highest compressive strength requirements:

    • Floors
    • Foundation slabs

     

     

    Thickness*

    in mm

    Dimensions* in mm

    Density (± 10%)

    (EN 1602) in kg/m3

    Thermal conductivity λD (EN ISO 10456)

    Compressive Strength
    (EN 826-A)

    40-160

    1200x600

    165

    ≤ 0.050 W/(m.K)

    ≥ 1600 kPa

     

    *Other dimensions and thicknesses available upon request

    Product data sheet PDS_PC_2-1-4_FLOOR_BOARD_F-UK_0413.pdf
    Safety data sheet SDS_PC_BOARDS_BLOCKS_PERINSUL_20121217-UK-AE-INT.pdf
    National BIM Library http://www.nationalbimlibrary.com/foamglas/foamglas-board-f
  • FOAMGLAS® READY BOARD T4+

    Application area:

    Insulation system allowing for torch-on and BUR roofing:

    • Flat roofs (mechanically fastened or glued on steel deck)
    • Below grade walls

     

    Thickness*

    in mm

    Dimensions* in mm

    Density (± 10%)

    (EN 1602) in kg/m3

    Thermal conductivity λD (EN ISO 10456)

    Compressive Strength
    (EN 826-A)

    40-180

    1200x600

    115

    ≤ 0.041 W/(m.K)

    ≥ 600 kPa

    Thickness*
    in in.

    Dimensions*
    in in.

    Density (Avg)
    ASTM C303 in lbs/ft3
    Thermal conductivity
    ASTM C 177, C 518
    Compressive Strength ± 10%
    ASTM C 240
    1.57” - 7.0” 48” x 24” 7.2 ≤ 0.28 Btu-in/hr.ft2.°F ≥ 87 psi

    *Other dimensions and thicknesses available upon request

    Product data sheet PDS_PC_2-1-5_READY_BOARD_T4-UK_0413.pdf
    Safety data sheet SDS_PC_BOARDS_BLOCKS_PERINSUL_20121217-EN00.pdf
    National BIM Library http://www.nationalbimlibrary.com/foamglas/foamglas-board-t4-plus
  • FOAMGLAS® READY BLOCK T4+

    Application area:

    Insulation system allowing for torch-on roofing:

    • Flat roofs (cold bonding on concrete using PC® 500)
    • Below grade walls (perimeter)

     

    Thickness*

    in mm

    Dimensions* in mm

    Density (± 10%)

    (EN 1602) in kg/m3

    Thermal conductivity λD (EN ISO 10456)

    Compressive Strength
    (EN 826-A)

    40-180

    600x450

    115

    ≤ 0.041 W/(m.K)

    ≥ 600 kPa

     

    *Other dimensions and thicknesses available upon request

    Product data sheet PDS_ReadyBlock_T4_20130812-UK.pdf
    Safety data sheet SDS_PC_BOARDS_BLOCKS_PERINSUL_20121217-UK-AE-INT.pdf
  • FOAMGLAS® READY BLOCK S3

    Application area:

    For Flat and Tapered Roofs.

    If required, FOAMGLAS® can be installed in 2 or more layers, for base layer use Slab S3.

     

    Thickness *
    in mm
    Dimensions *
    in mm
    Density (± 10%)
    (EN 1602) in kg/m3
    Thermal conductivity λD
    (EN ISO 10456)
    Compressive Strength
    (EN 826, A)
    40-180 600x450 130 ≤ 0,045 W/(m.K) ≥ 900 kPa

     

    * Other dimensions and thicknesses available upon request.

    Safety data sheet SDS_PC_BOARDS_BLOCKS_PERINSUL_20121217-UK-AE-INT.pdf
  • FOAMGLAS® READY BLOCK F

    Application area:

    For Flat and Tapered Roofs.

    If required, FOAMGLAS® can be installed in 2 or more layers, for base layer use Slab F.

     

    Thickness *
    in mm
    Dimensions *
    in mm
    Density (± 10%)
    (EN 1602) in kg/m3
    Thermal conductivity λD
    (EN ISO 10456)
    Compressive Strength
    (EN 826, A)
    40-160 600x450 165 ≤ 0,050 W/(m.K) ≥ 1600 kPa

     

    * Other dimensions and thicknesses available upon request.

    Safety data sheet SDS_PC_BOARDS_BLOCKS_PERINSUL_20121217-UK-AE-INT.pdf
  • FOAMGLAS® ROOF BOARD G2 T4+

    Application area:

    1. Can be used as a single layer or as a first layer in a two layer insulation system. Glassfiber liner allows the adhering of a second FOAMGLAS® layer. Glassfiber liner can receive a mechanically fixed or adhered waterproofing (ex. TPO, PVC or bituminous membrane):

     

    • On concrete: first or only layer in flat roof applications by cold bonding with PC® 500, PC® 600 Green or 2K PU ADCO One Step Millennium Green adhesive
    • On steeldeck: first or only layer in flat roof applications by cold bonding with PC® 11, PC® SK-FIX or 2K PU ADCO One Step Millennium Green adhesive

     

    2. Can be used as a top layer in a one or two layer system to receive a mechanically fixed or adhered waterproofing (ex. TPO, PVC or Bituminous membrane). First layer in a two layer insulation system. Glassfiber liner allows the adhering of a second FOAMGLAS® layer:

     

    • flat roofs (cold bonding on concrete using PU adhesive)
    • second layer can be adhered with PC® 58, PC® 500, 2K PU ADCO One Step Millennium Green adhesive, PC® SK-FIX.

     

    Second layer can be FOAMGLAS® ROOF BOARD G2 or ROOF BLOCK G1, FOAMGLAS® READY BOARD, FOAMGLAS® READY BLOCK. This second layer can be adhered with PC® 58, PC® 500, 2K PU ADCO One Step Millennium Green adhesive, PC® SK-FIX.

     

    Thickness *
    in mm
    Dimensions *
    in mm
    Density (± 10%)
    (EN 1602) in kg/m3
    Thermal conductivity λD
    (EN ISO 10456)
    Compressive Strength
    (EN 826, A)
    40-180 1200x600 115 ≤ 0,041 W/(m.K) ≥ 600 kPa

     

    * Other dimensions and thicknesses available upon request.

    Product data sheet PDS_ROOF_BOARD_G2_T4_20150415-UK.pdf
    Safety data sheet SDS_PC_BOARDS_BLOCKS_PERINSUL_20121217-UK-AE-INT.pdf
  • FOAMGLAS® ROOF BLOCK G1 T4+

    Application area:

    Can be used in a one or two layer system as a first or second layer.

     

    Possible finishing:

    • Second layer of FOAMGLAS® adhered with PC® 58, PC® 500, 2K PU ROYAL One Step Millennium Green adhesive, PC® SK-FIX.
    • Mechanically fixed fleece backed membrane (ex. TPO, PVC or bituminous membrane)
    • Fleece backed membrane glued with ROYAL PG1 adhesive or similar

     

    Thickness *
    in mm
    Dimensions *
    in mm
    Density (± 10%)
    (EN 1602) in kg/m3
    Thermal conductivity λD
    (EN ISO 10456)
    Compressive Strength
    (EN 826, A)
    40-180 600x450 115 ≤ 0,041 W/(m.K) ≥ 600 kPa

     

    * Other dimensions and thicknesses available upon request.

    Product data sheet PDS_ROOF_BLOCK_G1_T4_20150415-UK.pdf
    Safety data sheet SDS_PC_BOARDS_BLOCKS_PERINSUL_20121217-UK-AE-INT.pdf
  • FOAMGLAS® PERISAVE Base block

    Application area:

    Universal base element for passive house construction

     

    Thickness

    in mm

    Dimensions in mm

    Density (± 10%)

    (EN 1602) in kg/m3

    Thermal conductivity λD (EN ISO 10456)

    Compressive Strength
    (EN 826-A)

    280

    600x450

    100

    ≤ 0.038 W/(m.K)

    ≥ 400 kPa

     

    *Other dimensions and thicknesses available upon request

    Product data sheet PDS_FG_Perisave_Sockelblock_20151001-UK.pdf
    Safety data sheet SDS_PC_BOARDS_BLOCKS_PERINSUL_20121217-UK-AE-INT.pdf
  • FOAMGLAS® PERISAVE Marginal stop

    Application area:

    System element, which meets passive house requirements:

    • Marginal stop, insulation of formwork support in floor plate concreting

     

    Thickness

    in mm

    Dimensions in mm

    Density (± 10%)

    (EN 1602) in kg/m3

    Thermal conductivity λD (EN ISO 10456)

    Compressive Strength
    (EN 826-A)

    300

    600x300, 250

    100

    ≤ 0.038 W/(m.K)

    ≥ 400 kPa

     

    *Other dimensions and thicknesses available upon request

    Safety data sheet SDS_PC_BOARDS_BLOCKS_PERINSUL_20121217-UK-AE-INT.pdf
 
 
 