test

FOAMGLAS® TAPERED

  • FOAMGLAS® TAPERED: a cut-to-falls / cut-to-slope insulation system

    FOAMGLAS® TAPERED ROOF SYSTEM (TRS) is a cut-to-fall / cut-to-slope insulation system for flat roofs and floors. Depending on the requirements, the insulation is available in various slopes to assure good drainage.

     

    With FOAMGLAS® TAPERED ROOF the roof can be engineered to be lighter and safer without the problems associated with standing / ponding water. Often the need for a separate screed to falls is eliminated reducing materials and labour.


     

    Dimension * in mm Standard gradients * Types of slabs

    600x450

    1,1% or 1,7% or 2,2%

    • FOAMGLAS® T4+
    • FOAMGLAS® S3
    • FOAMGLAS® F
    • FOAMGLAS® READY BLOCK
    Dimensions in in. Standard gradients Types of slabs
    24” x 18” 1/8”, 1/4” and 1/2” / ft.
    • FOAMGLAS® T4+

    *Other dimensions and thicknesses available upon request

  • FOAMGLAS® TAPERED T3+ New

    Some application areas:

    • flat roofs: concrete, metal deck and special roofs
    • belowgrade: floors
    • interior insulation: floors

     

    Thickness*

    in mm

    Dimensions*

    in mm

    Density (± 10%)
    (EN 1602) in kg/m3
    Thermal conductivity λD (EN ISO 10456) Compressive Strength
    (EN 826-A)

    60-180

    600x450

    100

    ≤ 0.036 W/(m.K)

    ≥ 500 kPa


    *Other dimensions and thicknesses available upon request

    Product data sheet PDS_FG_TAPERED_T3plus_20170102-UK.pdf
  • FOAMGLAS® TAPERED READY BLOCK T3+ New

    Some application areas:

    • flat roofs: bonding on concrete, metal deck and special roofs
    • belowgrade: floors
    • interior insulation: floors

     

    Thickness*

    in mm

    Dimensions*

    in mm

    Density (± 10%)
    (EN 1602) in kg/m3
    Thermal conductivity λD (EN ISO 10456) Compressive Strength
    (EN 826-A)

    60-180

    600x450

    100

    ≤ 0.036 W/(m.K)

    ≥ 500 kPa


    *Other dimensions and thicknesses available upon request

    Product data sheet PDS_FG_TAPERED_READY_BLOCK_T3plus_20170102-UK.pdf
  • FOAMGLAS® TAPERED T4+

    Application area:

    FOAMGLAS® TAPERED ROOF SYSTEM, cut-to-falls / cut-to-slope insulation system:

    • Below grade floors and walls
    • Metal and special roofs
    • Interior insulation, floors

     

    Thickness*

    in mm

    Dimensions*

    in mm

    Density (± 10%)

    (EN 1602) in kg/m3

    Thermal conductivity λD (EN ISO 10456) Compressive Strength
    (EN 826-A)
    40-180

    600x450

    115

    ≤ 0.041 W/(m.K)

    ≥ 600 kPa

    Thickness*
    in in.

    Dimensions*
    in in.

    Density (Avg)
    ASTM C303 in lbs/ft3
    Thermal conductivity
    ASTM C 177, C 518
    Compressive Strength ± 10%
    ASTM C 240
    1.5”- 3.0”

    24” x 18”

    7.5

    ≤ 0.28 Btu-in/hr.ft2.°F

    ≥ 90 psi

     

    *Other dimensions and thicknesses available upon request

    Product data sheet PDS_PC_3-1-2_TAPERED_T4-UK_0413.pdf
    Safety data sheet SDS_PC_WF_T4_S3_F_HLB_ONE_TAPERED_20121227-UK-AE-US-INT.pdf
  • FOAMGLAS® TAPERED S3

    Application area:

    FOAMGLAS® TAPERED ROOF SYSTEM, cut-to-falls insulation system for high compressive strength requirements:

    • Flat roofs (f.i. trafficable decks)
    • Floors
    • Interior insulation floors

     

    Thickness*

    in mm

    Dimensions*

    in mm

    Density (± 10%)

    (EN 1602) in kg/m3

    Thermal conductivity λD (EN ISO 10456) Compressive Strength
    (EN 826-A)
    40-180

    600x450

    130

    ≤ 0.045 W/(m.K)

    ≥ 900 kPa

     

    *Other dimensions and thicknesses available upon request

    Product data sheet PDS_PC_3-1-3_TAPERED_S3-UK_0413.pdf
    Safety data sheet SDS_PC_WF_T4_S3_F_HLB_ONE_TAPERED_20121227-UK-AE-INT.pdf
  • FOAMGLAS® TAPERED F

    Application area:

    FOAMGLAS® TAPERED ROOF SYSTEM, cut-to-falls insulation system for highest compressive strength requirements:

    • Flat roofs (f.i. trafficable decks)
    • Floors

     

    Thickness*

    in mm

    Dimensions*

    in mm

    Density (± 10%)

    (EN 1602) in kg/m3

    Thermal conductivity λD (EN ISO 10456) Compressive Strength
    (EN 826-A)
    60-160

    600x450

    165

    ≤ 0.050 W/(m.K)

    ≥ 1600 kPa

     

    *Other dimensions and thicknesses available upon request

    Product data sheet PDS_PC_3-1-4_TAPERED_F-UK_0413.pdf
    Safety data sheet SDS_PC_WF_T4_S3_F_HLB_ONE_TAPERED_20121227-UK-AE-INT.pdf
  • FOAMGLAS® READY BLOCK TAPERED T4+

    Application area:

    TAPERED ROOF SYSTEM, cut-to-falls insulation system:

     

    • flat roofs (cold bonded with PC® adhesive to substructures)
    • metal and special roofs
    • belowgrade floors
    • interior insulation, floors

     

    Membranes can be torched directly onto the upper surface of the FOAMGLAS® READY BLOCK.

     

    Thickness *
    in mm
    Dimensions *
    in mm
    Density (± 10%)
    (EN 1602) in kg/m3
    Thermal conductivity λD
    (EN ISO 10456)
    Compressive Strength
    (EN 826, A)
    40-180 600x450 115 ≤ 0,041 W/(m.K) ≥ 600 kPa

     

    * Other dimensions and thicknesses available upon request.

    Product data sheet PDS_ReadyBlock_Tapered_T4_20131201-UK.pdf
    Safety data sheet SDS_PC_WF_T4_S3_F_HLB_ONE_TAPERED_20121227-UK-AE-US-INT.pdf
  • FOAMGLAS® READY BLOCK TAPERED S3

    Application area:

    READY BLOCK TAPERED ROOF SYSTEM, cut-to-falls insulation system:

     

    • flat roofs (cold bonding on concrete using PC® 500)
    • metal and special roofs
    • belowgrade floors and walls
    • interior insulation for floors

     

    Insulation system allowing for direct torch-on of waterproofing sheets.

     

    Thickness *
    in mm
    Dimensions *
    in mm
    Density (± 10%)
    (EN 1602) in kg/m3
    Thermal conductivity λD
    (EN ISO 10456)
    Compressive Strength
    (EN 826, A)
    40-180 600x450 130 ≤ 0,045 W/(m.K) ≥ 900 kPa

     

    * Other dimensions and thicknesses available upon request.

    Product data sheet PDS_ReadyBlock_Tapered_S3_20150401-UK.pdf
    Safety data sheet SDS_PC_WF_T4_S3_F_HLB_ONE_TAPERED_20121227-UK-AE-INT.pdf
  • FOAMGLAS® READY BLOCK TAPERED F

    Application area:

    READY BLOCK TAPERED ROOF SYSTEM, cut-to-falls insulation system:

     

    • flat roofs (cold bonding on concrete using PC® 500)
    • metal and special roofs
    • belowgrade floors and walls
    • interior insulation for floors

     

    Insulation system allowing for direct torch-on of waterproofing sheets.

     

    Thickness *
    in mm
    Dimensions *
    in mm
    Density (± 10%)
    (EN 1602) in kg/m3
    Thermal conductivity λD
    (EN ISO 10456)
    Compressive Strength
    (EN 826, A)
    40-180 600x450 165 ≤ 0,050 W/(m.K) ≥ 1600 kPa

     

    * Other dimensions and thicknesses available upon request.

    Product data sheet PDS_ReadyBlock_Tapered_F_20150401-UK.pdf
    Safety data sheet SDS_PC_WF_T4_S3_F_HLB_ONE_TAPERED_20121227-UK-AE-INT.pdf
  • FOAMGLAS® TAPERED ROOF BLOCK G1 T4+

    Application area:

    ROOF BLOCK G1 TAPERED ROOF SYSTEM, cut-to-falls insulation system:

     

    • flat roofs (cold bonding on concrete using PC® 500)
    • metal and special roofs
    • below grade floors and walls
    • interior insulation for floors

     

    Can be used in a one or two layer system as a first or second layer.

     

    Possible finishing:

    • Second layer of FOAMGLAS® adhered with PC® 58, PC® 500, 2K PU ROYAL One Step Millennium Green adhesive, PC® SK-FIX.
    • Mechanically fixed fleece backed membrane (ex. TPO, PVC or bituminous membrane)
    • Fleece backed membrane glued with ROYAL PG1 adhesive or similar

     

    Thickness *
    in mm
    Dimensions *
    in mm
    Density (± 10%)
    (EN 1602) in kg/m3
    Thermal conductivity λD
    (EN ISO 10456)
    Compressive Strength
    (EN 826, A)
    40-180 600x450 115 ≤ 0,041 W/(m.K) ≥ 600 kPa

     

    * Other dimensions and thicknesses available upon request.

    Product data sheet PDS_ROOF_BLOCK_G1_T4_20150415-UK.pdf
    Safety data sheet SDS_PC_BOARDS_BLOCKS_PERINSUL_20121217-UK-AE-INT.pdf
 
 
 

Events